Configuration
Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
224
of 814
3.4
3.4.12.3 Description of the Parameter
124.1 Configuration Mode
Configuration of the measuring encoder
124.24 Encoder 2 trigger digital
input TP2 neg. edge
angle
UDINT 0 0xFFFFFFFF 0 1:1 X X
124.25 Encoder 2 trigger zero
pulse pos. edge revolu
-
tions
UDINT 0 0xFFFFFFFF 0 1:1 X X
124.26 Encoder 2 trigger zero
pulse pos. edge angle
UDINT 0 0xFFFFFFFF 0 1:1 X X
124.27 Encoder 2 trigger zero
pulse neg. edge revolu
-
tions
UDINT 0 0xFFFFFFFF 0 1:1 X X
124.28 Encoder 2 trigger zero
pulse neg. edge angle
UDINT 0 0xFFFFFFFF 0 1:1 X X
124.30 DS402 mode UDINT 0 0xFFFFFFFF 0x00100100 1:1 X
124.31 DS402 touch probe 1
pos. value
UDINT 0 0xFFFFFFFF 0 Inc 1:1 X
124.32 DS402 touch probe 1
neg. value
UDINT 0 0xFFFFFFFF 0 Inc 1:1 X
124.33 DS402 touch probe 2
pos. value
UDINT 0 0xFFFFFFFF 0 Inc 1:1 X
124.34 DS402 touch probe 2
neg. value
UDINT 0 0xFFFFFFFF 0 Inc 1:1 X
NOTE!
All measurements are inactive during the change of the configuration!
Bit Meaning
Encoder 1
0…2 Measurement "Encoder 1 with Trigger digital input TP1"
0 Activation channel measurement positive edge
(Enc1TrDi1PosValRev/Enc1TrDi1PosValPhi)
0: switch off
1: switch on