EasyManua.ls Logo

Baumuller b maXX BM5800 - Description of the Parameter

Baumuller b maXX BM5800
816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration
Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
224
of 814
3.4
3.4.12.3 Description of the Parameter
124.1 Configuration Mode
Configuration of the measuring encoder
124.24 Encoder 2 trigger digital
input TP2 neg. edge
angle
UDINT 0 0xFFFFFFFF 0 1:1 X X
124.25 Encoder 2 trigger zero
pulse pos. edge revolu
-
tions
UDINT 0 0xFFFFFFFF 0 1:1 X X
124.26 Encoder 2 trigger zero
pulse pos. edge angle
UDINT 0 0xFFFFFFFF 0 1:1 X X
124.27 Encoder 2 trigger zero
pulse neg. edge revolu
-
tions
UDINT 0 0xFFFFFFFF 0 1:1 X X
124.28 Encoder 2 trigger zero
pulse neg. edge angle
UDINT 0 0xFFFFFFFF 0 1:1 X X
124.30 DS402 mode UDINT 0 0xFFFFFFFF 0x00100100 1:1 X
124.31 DS402 touch probe 1
pos. value
UDINT 0 0xFFFFFFFF 0 Inc 1:1 X
124.32 DS402 touch probe 1
neg. value
UDINT 0 0xFFFFFFFF 0 Inc 1:1 X
124.33 DS402 touch probe 2
pos. value
UDINT 0 0xFFFFFFFF 0 Inc 1:1 X
124.34 DS402 touch probe 2
neg. value
UDINT 0 0xFFFFFFFF 0 Inc 1:1 X
NOTE!
All measurements are inactive during the change of the configuration!
Bit Meaning
Encoder 1
0…2 Measurement "Encoder 1 with Trigger digital input TP1"
0 Activation channel measurement positive edge
(Enc1TrDi1PosValRev/Enc1TrDi1PosValPhi)
0: switch off
1: switch on

Table of Contents