Configuration
Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
204
of 814
3.4
3.4.10.3 Description of the Parameters
116.1 Status digital inputs
Status of the digital inputs. Bits 23 ... 16 display the hardware status, i.e., whether the in-
put has been set active. Bits 7 ... 0 show the logical states of the inputs according to their
configured inversion (see Bit 15 in each case in the mode digital input 1
Z116.2, mode
digital input 2 Z116.8, etc. parameters).
116.2 Mode digital input 1
Operating mode of digital input 1.
Bit 15 can be used to define whether the input linking for the functions for which parame-
ters can be set via Bits 0...5 should operate with inversion or directly.
Bit 6 is used to determine which axis the special function selected with Bits 0...5 should
apply to.
In addition Bit 7 is used to determine whether the selected special function should be ap-
plied to both axes at the same time. These two bits thus apply only to the special func-
tions. The axis reference for input linking is specified with the appropriate DIx axis Index
parameter.
If the input is permanently linked to the "Pulse enable" function, the logical inversion has
no effect on the function.
The user can only set the inversion of bit 15 and the evaluation of bit 14.
Bit # Meaning
0 Logical status of Input 1 0 = inactive
1 = active
1 Logical status of Input 2 0 = inactive
1 = active
15 ... 2 Reserved
16 HW status of Input 1 0 = inactive
1 = active
17 HW status of Input 2 0 = inactive
1 = active
31 ... 18 Reserved