EasyManua.ls Logo

Baumuller b maXX BM5800 - Description of the Parameters

Baumuller b maXX BM5800
816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of the Software Modules and Parameters
Parameter manual b maXX BM5800
Document No.: 5.16029.03
325
of 814
3
3.5.2.13 Description of the Parameters
105.1 Command
Commands for data set management:
The commands Save (1), Load (2), Delete (3) and Set Default Values (5) act on all axes.
The other commands act on the selected axis only.
105.2 Status
Displays the status of the data set management system.
While the command is being processed, the value 1 (RC_BUSY) is displayed.
After the command has completed the value 3, for RC_DONE, is displayed or possibly
the code for any error that occurred during processing.
List of the most frequent status messages (RC codes):
Value Meaning
0 Resets the DSM; the message list is deleted
1 Saves the parameter set in Flash
2 Loads the parameter set from Flash
3 Deletes the parameter set in Flash
4 Set all parameters in the target data set to the default value
5 Sets all savable parameters to the default value
6 Create Data Set X (target data set)
7 Delete Data Set X (target data set)
8 Copy the source data set to the target data set
9 Read the source data set from Flash again
10 Set standard values for all axis specific parameters of an axis
Value RC Code Meaning
0 RC_NO_ERROR No command executed yet or else Reset
command executed.
1 RC_BUSY A command is being executed.
3 RC_DONE A command has completed successfully
1400 RC_ERR_DSV Error while loading or saving the parame-
ter set (see Message parameters)

Table of Contents

Related product manuals