Set Value Generators
Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
390
of 814
3.6
3.6.5.9 Description of the Parameters
159.1 Mode
Control of cam generator
159.2 Cam options
Settings of the different operating modes and functions of the cam generator.
Bit no. Meaning
0 Activation of the cam generator
Request of state change in state machine of cam generator from "init" to
"active".
0 1: Activation of the cam generator
1 Starting the cam generator
The processing of the cam is initiated with a rising edge in this bit. This
causes a state change of the state machine of the cam generator from
"active" to "run".
0 1: Start the processing of the cam
2 The processing of the cam generator is stopped. The table index is reset.
0: Cam generator can be started and operated
1: Cam generator is stopped and is reset
3 Stops the processing at time-controlled processing. As soon as the bit is
reset, processing is started again at the same point (interrupt function).
0: Time-controlled processing is running
1: Time-controlled processing is stopped
4 … 6 Reserved
7 The actual valid cam is invalidated. There is no valid cam available in the
RAM of the controller.
0 1: The actual cam is deleted in the RAM
Bit no. Meaning
0 0: time-controlled processing
1: parameter-controlled processing
1 Time-controlled processing, only
0: time control via the table index
1: time control with virtual master axis
2 Time control with virtual master axis and parameter-controlled processing,
only
0: no interpolation
1: active interpolation