Configuration
Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
238
of 814
3.4
1
) Z131.9 bit 14 Factor Group must be activated
2
) Z121.1 bit 4 modulo actual position value must be activated
124.31 DS402 touch probe 1 pos. value
DS402 touch probe object 0x60BA
The source is selected in Z124.30.
The following scalings are possible:
m according to Z124.30 bits 9 ... 4 (Z124.30 bits 2 ... 1 = 00) or
m with the Factor Group weightings from Z179.2 to Z179.9 (Z124.30
bit 2 ... 1 = 01) or
m position system of the modulo actual position value Z121.17 (Z124.30
bit 2 ... 1 = 10)
124.32 DS402 touch probe 1 neg. value
DS402 touch probe object 0x60BB
The source is selected in Z124.30.
The following scalings are possible:
m according to Z124.30 bits 9 ... 4 (Z124.30 bits 2 ... 1 = 00) or
m with the Factor Group weightings from Z179.2 to Z179.9 (Z124.30
bit 2 ... 1 = 01) or
m position system of the modulo actual position value Z121.17 (Z124.30
bit 2 ... 1 = 10)
23 … 20 Source for DS402 touch probe 2 (TP2)
(Z124.33 / Z124.34, object 0x60BC / 0x60BD)
Value:
0: Encoder 1 trigger digital input TP1
1: Encoder 1 trigger digital input TP2
2: Encoder 1 trigger zero pulse
3: Encoder 2 trigger digital input TP1
4: Encoder 2 trigger digital input TP2
5: Encoder 2 trigger zero pulse
6 … 15: Reserved
31 … 24 Reserved