Description of the Software Modules and Parameters
Parameter manual b maXX BM5800
Document No.: 5.16029.03
239
of 814
3
124.33 DS402 touch probe 2 pos. value
DS402 touch probe object 0x60BC
The source is selected in Z124.30.
The following scalings are possible:
m according to Z124.30 bits 9 ... 4 (Z124.30 bits 2 ... 1 = 00) or
m with the Factor Group weightings from Z179.2 to Z179.9 (Z124.30
bit 2 ... 1 = 01) or
m position system of the modulo actual position value Z121.17 (Z124.30
bit 2 ... 1 = 10)
124.34 DS402 touch probe 2 neg. value
DS402 touch probe object 0x60BD
The source is selected in Z124.30.
The following scalings are possible:
m according to Z124.30 bits 9 ... 4 (Z124.30 bits 2 ... 1 = 00) or
m with the Factor Group weightings from Z179.2 to Z179.9 (Z124.30
bit 2 ... 1 = 01) or
m position system of the modulo actual position value Z121.17 (Z124.30
bit 2 ... 1 = 10)