EasyManua.ls Logo

Baumuller b maXX BM5800 - Page 141

Baumuller b maXX BM5800
816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of the Software Modules and Parameters
Parameter manual b maXX BM5800
Document No.: 5.16029.03
141
of 814
3
Figure 48: Sine/Cosine traces and instantaneous amplitude of the encoder signal
Sector Monitoring
The sector sequence at the sampling of the encoder traces (sine or cosine signal) is an-
alyzed at this monitoring. Here it is assumed that the sampling rate is at least 4 times the
signal frequency and therefore each quadrant of a signal period is at least sampled once.
Monitoring of square-wave incremental encoder
The levels of the encoder signal are monitored separately at a square-wave incremental
encoder, because a monitoring of the amplitude using sin² +cos² is only restricted possi
-
ble. The zero trace (zero pulse) is not monitored.