Description of the Software Modules and Parameters
Parameter manual b maXX BM5800
Document No.: 5.16029.03
245
of 814
3
150.8 Tn PID controller 1
Integral action time of the PID controller 1.
150.9 Td PID controller 1
Derivative time of the PID controller 1.
150.10 Pt1 time constant PID controller 1
Time constant of the PT1 filter in the D leg of the PID controller. If the value „0“ is speci-
fied, the signal will be transmitted unfiltrated.
150.11 Output upper limit PID controller 1
Upper limit of the PID controller output.
If the output is limited with this limit, it will be signalized in Z150.2 bit 4.
150.12 Output lower limit PID controller 1
Lower limit of the PID controller output.
If the output is limited with this limit, it will be signalized in Z150.2 bit 4.
NOTE!
If the upper limit is greater than the maximum value of the linked target parameter,
then the output is limited at writing on the target parameter to the maximum value of
the linked target parameter if necessary. This will be signalized in
Z150.2 bit 8.
NOTE!
If the lower limit is less than the minimum value of the linked target parameter, then
the output is limited at writing on the target parameter to the minimum value of the
linked target parameter if necessary. This will be signalized in
Z150.2 bit 8.