3.4
156.8 Max. jitter positive
Maximum jitter of the synchronization signal in positive direction (measured interval
greater than the set interval).
156.9 Max. jitter negative
Maximum jitter of the synchronization signal in negative direction (measured interval low-
er than the set interval).
Display of the maximum jitter can be reset by a write access with any value.
156.15 Time fieldbus write access
Instant of time of write access of the fieldbus processor on the DPRAM referring to the
Sync signal.
156.16 Time DSP read access
Instant of time of read access of the controller processor on the DPRAM referring to the
Sync signal.
156.17 Time DSP write access
Instant of time of write access of the controller processor on the DPRAM referring to the
Sync signal.
156.18 Time fieldbus read access
Instant of time of read access of the fieldbus processor on the DPRAM referring to the
Sync signal.
156.19 Time fieldbus read to DSP read
Period between the read accesses of the controller processor and the fieldbus processor.