Management
Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
290
of 814
3.5
n OPERATION ENABLED
m The parameters for the application can be changed
m Drive function is enabled
m The operationally ready relay is ON (drive is operationally ready)
n OPERATION INHIBIT ACTIVE
m The parameters for the application can be changed
m Drive function is enabled
m "Inhibit Operation" command is executed
m The operationally ready relay is ON (drive is operationally ready)
n DRIVE SHUT-DOWN ACTIVE
m The parameters for the application can be changed
m Drive function is enabled
m "Shut-down" command is executed
m The operationally ready relay is ON (drive is operationally ready)
n QUICK STOP ACTIVE
m The parameters for the application can be changed
m "Quick Stop" command is executed
m Drive function is enabled
m The operationally ready relay is ON (drive is operationally ready)
n ERROR RESPONSE ACTIVE
m The parameters for the application can be changed
m An error-dependent action is carried out
m Drive function can be enabled
m The operationally ready relay is ON (drive is operationally ready)
n ERROR
m The parameters for the application can be changed
m The drive function is inhibited
m The operationally ready relay is OFF (drive is not operationally ready)