Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
408
of 814
3.7
A correction signal with selectable progression is connected depending on the set value
or actual value speed of the drive.
Three-point with hysteresis and dead zone:
Figure 103: Three-point with hysteresis and dead zone
Three different values will be connected. A hysteresis Z154.9 can be taken into account
to avoid unintentional switching operations at the speed threshold if the speed signal is
noisy.
Three-point with ramp
Figure 104: Three-point with ramp
A ramp function value is set between the constant connection values below the lower
speed threshold and above the upper speed threshold. Faults at the switching edges are
avoided by the continuous run.
5000_0209_rev02_int.cdr
><154.7
><154.6
><154.3
><154.5
><154.4
><154.4
+ ><154.9
><154.3
- ><154.9
Output
Speed
5000_0210_rev01_int.cdr
><154.7
><154.3
><154.5
><154.4
Output
Speed