Operating Modes
Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
526
of 814
3.8
Bit 6: Error - Command aborted at positive stop
The error is generated if the command is aborted at following states:
the N=0 message is generated and
the clamping moment is reached,
but the message "Positive stop reached" was not generated by the controller yet
(
Z121.22 Status bit 10 = 0).
Bit 8:
Copy of the standstill message (Z6.2) of the motor encoder, the bit is updated at ac-
tive command only.
Bit 9:
The bit is set if the torque actual value has reached the clamping torque. The bit is up-
dated independently on the n=0 message as far as the command is active.
Bit 10:
Message "Positive stop reached" is set if the n=0 message and the message "Clamp-
ing torque reached" are present constantly during the Blocking time (Z120.11).
121.23 Mode positive stop drive
Note:
Bit 2:
If the bit is set, the parameter Z120.12 Homing torque limit [%] related to the maxi-
mum available torque current Z19.8 is not evaluated during the command.
121.24 Positive stop position
When reaching the positive stop (Z121.22 bit 10 = 1 "Positive stop reached") the con-
troller stores the current position actual value (Z121.9) in this parameter.
This value is the base for positive stop monitoring via monitoring window.
Bit Meaning
0 -1 Monitoring positive stop
00: no monitoring
01: via monitoring window positive stop Z121.25
10: via N=0 message
11: Reserved
2 0: torque reduction via Z120.12 active
1: torque reduction via Z120.12 disabled
15 ... 3 Reserved