3.3
102.33 Device article number
Article number of the device as a 32 bit numerical value.
102.35 Device type code
Complete BM device type code of the form:
BM58XX – XX – XXXXXX – XXXXXX – XXXXXX – XXX – XXXX – XXXX - EXX
Example of a type code:
102.39 Fpga Id CU
FPGA identification of the fieldbus connection.
139.1 Password
Password for protecting access to system parameters. The value displayed corresponds
to the password level.
Power
unit 1
Power
unit 2
Power
unit 3
BM5807 - SG - 322112 - 252112 - 222111 - 001 - 0000 - 0110 - E80
Identifier
in the type
code
Safety functionalities
0 No functionality
1 STO
NOTE!
The controller has several possible interfaces for accessing parameters (serial inter-
face as well as up to three EOE channels).
The handling of the password-protected levels is not interface-oriented. If an inter-
face channel switches to a password level, the corresponding access permission
also applies to all the other channels.