166.3 Current threshold motor
Maximum total current for motor operation in percent of the Max. drive current Z19.6.
166.4 Current threshold generator
Maximum total current for generator operation in percent of the Max. drive current Z19.6
166.5 Zero voltage
DC voltage at an electrical frequency of 0 Hz
166.6 Input reference frequency
Electrical reference frequency in 32-bit resolution
Standardization: 100% = maximum frequency (Z166.10)
166.7 Rising time
Ramp up time to 1000 rpm electrical
166.9 Slip compensation
Additional frequency depending on the current.
The slip compensation is only active if the speed control is switched off.
6 Acceleration from speed 0
7 Reserved
8 New reference frequency
9 Direction of acceleration inverted
15 ... 10 Reserved