7
7
7-4
7-4
Error Codes > Error Codes
Error Codes > Error Codes
Code Detection description Remedy
E225 0001
Light intensity of a lamp is
less or equal to the criteria
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
following remedies.
(1) Check the connection of Flat Cable between Main
Controller Board (J5) and Contact Sensor.
(2) Replace the Flat Cable between Main Controller
Board (J5) and Contact Sensor.
(3) Replace the Contact Sensor.
(4) Replace the Main Controller Board.
E301 0001
Insufcient light intensity in
shading
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
following remedies.
(1) Check the connection of Flat Cable between Main
Controller Board (J5) and Contact Sensor.
(2) Replace the Flat Cable between Main Controller
Board (J5) and Contact Sensor.
(3) Replace the Contact Sensor.
(4) Replace the Main Controller Board.
E736 0000
Communication error with
CCU/modem, or no FAX
board installed on FAX
model.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
following remedies.
(1) Check the connection of connectors between the
Main Controller Board (J601, J602) and the FAX-
NCU Board (J1201, J1204).
(2) Replace the connectors between the Main Controller
Board (J601, J602) and the FAX-NCU Board (J1201,
J1204).
(3) Replace the FAX-NCU Board.
(4) Replace the Main Controller Board.
E740 0002
Error detection on either
Network Board or Mac
address
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
following remedies.
(1) Check the connection of the network cable.
(2) Replace the Main Controller Board.
Code Detection description Remedy
E744
0002 Language le error
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
following remedies.
Update the set of the Controller Firmware
4000
Engine ID error (Invalid
engine connection is
detected)
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
following remedies.
(1) Check the Engine Controller Board.
(2) Update the Engine Firmware.
(3) Update the set of the Controller Firmware
6000
Communication error with
Wireless LAN board.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
following remedies.
(1) Replace the Wireless LAN Board.
(4) Replace the Main Controller Board.
E806 0000
Fan Motor cannot rotate at
specied revolution speed.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
following remedies.
(1) Replace the Main Fan Unit.
(2) Replace the Engine Controller Board.