8
8
8-14
8-14
Service Mode > FAX > List of NCU > PBX BUSY TONE
Service Mode > FAX > List of NCU > PBX BUSY TONE
■
PBX DIAL TONE
(1) Bit switch
Bit No. Function 1 0
Bit 0
Frequency detection method Modem Tonal counter
Bit 1
Bit 2
Signal frequency Changed Not changed
Bit 3
Bit 4
Judgment of intermittent signal Start from valid ON
signal
Start from either valid
ON signal or OFF signal
Bit 5
Bit 6
Signal form Continuous Intermittent
Bit 7
Signal detection Detected Not detected
(2) Numeric value parameter
Parameter No. Function Setting range
01;
T0 timer 0 to 9999 (x10ms)
02;
T1 timer 0 to 9999 (x10ms)
03;
T2 timer 0 to 9999 (x10ms)
04;
T3 timer 0 to 9999 (x10ms)
05;
T4 timer 0 to 9999 (x10ms)
06;
Signal detection table 0 to 16
07;
Signal detection level 0 to 9
08;
Number of valid tone detection 0 to 9999 (times)
■
PBX BUSY TONE
(1) Bit switch
Bit No. Function 1 0
Bit 0
Bit 1
Bit 2
Signal frequency Changed Not changed
Bit 3
Bit 4
Judgment of intermittent signal Start from valid ON
signal
Start from either valid
ON signal or OFF signal
Bit 5
Bit 6
Signal form Continuous Intermittent
Bit 7
Signal detection Detected Not detected
T-8-38
T-8-39
T-8-40
(2) Numeric value parameter
Parameter No. Function Setting range
01;
T0 timer 0 to 9999 (x10ms)
02;
T1 timer 0 to 9999 (x10ms)
03;
T2 timer 0 to 9999 (x10ms)
04;
T3 timer 0 to 9999 (x10ms)
05;
T4 timer 0 to 9999 (x10ms)
06;
Signal detection table 0 to 16
07;
Signal detection level 0 to 9
08;
Number of valid tone detection 0 to 9999 (times)
T-8-41