EasyManua.ls Logo

Canon imageCLASS LBP6780dn - Page 249

Canon imageCLASS LBP6780dn
270 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
5
5-54
5-54
Troubleshooting > Updater > Error Messages
Troubleshooting > Updater > Error Messages
No. Messages Timing of display Cause Remedy
13 Delivery Error
Error Code: [xxx]
UGW linkage (Update
Firmware screen)
eRDS sent an order but Updater failed to connect
to the server.
Conduct a communication test to analyze the cause of the error. After solving the cause,
resend the order from the eRDS.
If it recurs, obtain the log etc. (Refer to "System Management Operations" under “Version
Upgrade”of "Updater" in Chapter 6 “Troubleshooting” of this manual.) and contact
Support Div. of the sales company.
The delivery server stopped. Contact the sales company's Support Department. After conrming restoration of the
delivery server, re-execute the job.
If it recurs, obtain the log etc. (Refer to "System Management Operations" under “Version
Upgrade”of "Updater" in Chapter 6 “Troubleshooting” of this manual.) and contact
Support Div. of the sales company.
The scheduled data and time acquired from delivery
server does not exist.
Do the delivery setting from UGW again.
If it recurs, obtain the log etc. (Refer to "System Management Operations" under “Version
Upgrade”of "Updater" in Chapter 6 “Troubleshooting” of this manual.) and contact
Support Div. of the sales company.
14 Delivery Error
Delivery Time
Delivery Firmware Label
Delivery Firmware version
Error Code: [ xxx ]
UGW linkage (Update
Firmware screen)
The scheduled date and time acquired from delivery
server was before current time (15 or more min had
passed).
Do the delivery setting from UGW again.
If it recurs, obtain the log etc. (Refer to "System Management Operations" under “Version
Upgrade”of "Updater" in Chapter 6 “Troubleshooting” of this manual.) and contact
Support Div. of the sales company.
Immediate download
(Update Firmware screen)
At the time of immediate download, turned OFF and
then ON the power of device main body.
Re-execute the job.
If it recurs, obtain the log etc. (Refer to "System Management Operations" under “Version
Upgrade”of "Updater" in Chapter 6 “Troubleshooting” of this manual.) and contact
Support Div. of the sales company.
15 Applicable rmware is not registered. On-site (error dialogue) At the user site, no latest rmware exists. This means the current rmware is the latest, so this error has no impact.
But when the latest rmware to be retrieved must exist e.g. released new rmware
information has been notied, contact Field Support Group in the sales company.
No applicable rmware exists on CDS, so the
service person can't select any applicable rmware.
Contact the sales company's Support Department.
16 Restart failed.
Turn the main power OFF and ON.
Manual update (error
dialogue)
An error occurred at the time of the device restart. After turning OFF and then ON the main power of the device, re-execute the job.
If it recurs, obtain the log etc. (Refer to "System Management Operations" under “Version
Upgrade”of "Updater" in Chapter 6 “Troubleshooting” of this manual.) and contact
Support Div. of the sales company.
Automatic update (error
dialogue)
An error occurred at the time of the device restart. After turning OFF and then ON the main power of the device, re-execute the job.
If it recurs, obtain the log etc. (Refer to "System Management Operations" under “Version
Upgrade”of "Updater" in Chapter 6 “Troubleshooting” of this manual.) and contact
Support Div. of the sales company.
17 Specify [E-Mail Address] with up to 64
characters.
At the time of periodical
update setting
The specied E-mail address exceeded 64
characters.
Specify E-mail address within 64 characters.
18 The following characters cannot be
used for the [E-Mail Address]:
, : ; “ ( ) [ ] < > \
At the time of periodical
update setting
The E-mail address was including the characters
which could not be used.
Do not specify E-mail address with characters which cannot be used.
19 Specify [Comments] with up to 128
characters.
At the time of periodical
update setting
Comments exceeded 128 characters. Specify comments within 128 characters.
20 The [Delivery Server URL] is incorrect. In setting with the deliver
server URL.
The specied deliver server URL is wrong. Enter the right URL(https://device.c-cdsknn.net/cds_soap/updaterif)
T-5-56