Technology > Fixing System > Fixing control circuit > Failure detection
Technology > Fixing System > Fixing control circuit > Failure detection
■
Protective function
The protective function detects an abnormal temperature rise of the xing unit and interrupts
power supply to the xing heater.
The following three protective components prevent an abnormal temperature rise of the xing
heater:
• DC controller
• Fixing heater safety circuit
• Thermoswitch
1) DC controller
The DC controller interrupts power supply to the xing heater when it detects an abnormal
temperature of the xing heater.
2) Fixing heater safety circuit
The xing heater safety circuit interrupts power supply to the xing heater when the
detected temperature of the main and sub thermistors is abnormal.
3) Thermoswitch
The contact of the thermoswitch is broken to interrupt power supply to the xing heater
when the thermoswitch detects an abnormal temperature of the xing heater.
■
Failure detection
The DC controller determines a xing unit failure, deactivates the FIXING HEATER
CONTROL signal,releases the relay to interrupt power supply to the xing heater and noties
the formatter of a failure state when it encounters the following conditions:
1) Start-up failure
• If the main thermistor does not detect a specied temperature during the start-up process
of the
heater in the wait period.
• If the main thermistor does not detect a specied temperature during the heater
temperature control in the initial rotation period.
2) Abnormal low temperature
• If the main thermistor detects an abnormal low temperature of the xing unit during the
printing operation.
• If the sub thermistor detects an abnormal low temperature of the xing unit during the
printing operation.
3) Abnormal high temperature
• If the main thermistor detects an abnormal high temperature of the xing unit.
• If the sub thermistor detects an abnormal high temperature of the xing unit.
4) Frequency detection circuit failure
• If a specied frequency of the ZERO CROSSING signal is not detected within a specied
period after the printer is turned on.