This unit has two power supply connections. All connections must be removed to de-energize the unit.
Statement 1028
Warning
This product relies on the buildings installation for short-circuit (overcurrent) protection. Ensure that the
protective device is rated not greater than: AC power supplies 20 A and DC power supplies 30 A. Statement
1005
Warning
This section provides the procedures for connecting AC-input, 48 VDC input power, and the +24 VDC input
power to your Cisco ASR 1002 Router.
Detailed instructions for removing and replacing the Cisco ASR 1002 Router AC and DC power supplies
are in Chapter 14, Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers.
Note
Connecting AC Input Power to Cisco ASR 1002 Router
To connect AC power to the Cisco ASR 1002 Router, follow these steps:
SUMMARY STEPS
1.
At the rear of the router, check that the power switch is in the Off (O) position.
2.
Insert the AC power cable into the power supply AC inlet.
3.
To ensure that the AC power cord does not interfere with other cables or wires, dress the AC power cable
in one of the following ways.
4.
Plug the AC power supply cable into the AC power source.
DETAILED STEPS
Step 1
At the rear of the router, check that the power switch is in the Off (O) position.
Turn the power switch to the On (|) position after both sides of the power cord are connected.Note
Cisco ASR 1000 Series Router Hardware Installation Guide
256
Cisco ASR 1002 Router Overview and Installation
Connecting AC Input Power to Cisco ASR 1002 Router

Table of Contents

Other manuals for Cisco ASR 1001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 1001 and is the answer not in the manual?

Cisco ASR 1001 Specifications

General IconGeneral
Ethernet LANYes
Cabling technology10/100/1000Base-T(X)
Networking standards-
Ethernet LAN data rates10, 100, 1000 Mbit/s
Ethernet interface typeGigabit Ethernet
USB ports quantity1
Ethernet LAN (RJ-45) ports4
VPN tunnels quantity8000
Product colorGray
Rack capacity1U
AC input voltage85 - 264 V
Power source typeAC
AC input frequency50 - 60 Hz
Power consumption (typical)250 W
SafetyUL60950-1 CSA, C22.2 No. 60950-1-03, EN 60950-1, IEC 60950-1, AS/NZS 60950.1
CertificationFCC 47CFR15 Class A AS/NZS CISPR 22 CISPR 22 Class A EN55022 Class A ICES-003 Class A VCCI Class A CNS-13438 Class A EN61000-3-2 EN61000-3-3
Internal memory8192 MB
Operating altitude0 - 3048 m
Storage temperature (T-T)0 - 50 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)5 - 90 %
Weight and Dimensions IconWeight and Dimensions
Depth461.5 mm
Width439.42 mm
Height43.43 mm
Weight11350 g