Step 11
Replace the terminal block plastic cover, which is slotted and keyed to fit correctly over the terminal block; then tighten
the black screw (use the screwdriver to tighten the screw to a torque of 5 in-lbs / 1 per). See the following figure.
Figure 273: Cisco ASR 1006 Router DC Power Supply Terminal Block Plastic Cover and Switch
Terminal block plastic cover
black screw
2DC power supply On/Off
switch
1
Step 12
Remove the tape from the circuit-breaker On/Off switch.
Step 13
Switch the circuit breaker On/Off switch to the On (|) position.
What to Do Next
The requirement for maximum torque applied to the power or ground Kepnuts must be 8 in-lb when the
power or ground lug is not present.
Note
This completes the procedure for installing the DC power supply into the Cisco ASR 1006 Router.
Removing and Replacing the Cisco ASR 1004 Router Power
Supplies
The Cisco ASR 1004 Router contains power supplies that are field replaceable units. This section contains
the following topics:
Cisco ASR 1000 Series Router Hardware Installation Guide
555
Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
Removing and Replacing the Cisco ASR 1004 Router Power Supplies

Table of Contents

Other manuals for Cisco ASR 1001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 1001 and is the answer not in the manual?

Cisco ASR 1001 Specifications

General IconGeneral
Ethernet LANYes
Cabling technology10/100/1000Base-T(X)
Networking standards-
Ethernet LAN data rates10, 100, 1000 Mbit/s
Ethernet interface typeGigabit Ethernet
USB ports quantity1
Ethernet LAN (RJ-45) ports4
VPN tunnels quantity8000
Product colorGray
Rack capacity1U
AC input voltage85 - 264 V
Power source typeAC
AC input frequency50 - 60 Hz
Power consumption (typical)250 W
SafetyUL60950-1 CSA, C22.2 No. 60950-1-03, EN 60950-1, IEC 60950-1, AS/NZS 60950.1
CertificationFCC 47CFR15 Class A AS/NZS CISPR 22 CISPR 22 Class A EN55022 Class A ICES-003 Class A VCCI Class A CNS-13438 Class A EN61000-3-2 EN61000-3-3
Internal memory8192 MB
Operating altitude0 - 3048 m
Storage temperature (T-T)0 - 50 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)5 - 90 %
Weight and Dimensions IconWeight and Dimensions
Depth461.5 mm
Width439.42 mm
Height43.43 mm
Weight11350 g