Page #66 background imageLoading...
Page #66 background image
ResultASR1000-SIPASR1000-ESPASR1000-RPRouter
Integrated
embedded services
processor
Cisco ASR 1001
Router
SIP-40 disabled
The following may be the outcome when using unsupported Cisco ASR 1000 components in a high-availability
feature configuration:
Unsupported ASR1000-RP in a redundant Cisco ASR 1006 configurationIf you insert an Cisco
ASR1000-RP1 or RP2 in an ASR 1006 redundant setup, the following occurs:
The standby ASR1000-RP card is disabled and this error message prints on the active RP console:
Error message: %CMRP-3-RP_MISMATCH: [chars] has been held in reset because the part number
differs from that of the active RP.
rp_fru: R0/R1
Reason: The part number read from the FRU IDPROM is not compatible with part number of the active
ASR1000-RP; as a result it may not act as a standby.
Recommended action: Remove the FRU from the chassis
Unsupported Cisco ASR 1000 series router power supplyIf you insert the Cisco ASR 1013 router
power supply into the Cisco ASR 1006 Router or insert the Cisco ASR 1006 Router power supply into
the Cisco ASR 1013 Router, the following occurs:
The following error message displays when detected and then periodically after that (every 1 hour) until the
problem is corrected.
Error message: %CMRP-3-UNSUPPORTED_PEM: [chars] in slot [chars] is not supported with [chars]
and it needs to be replaced immediately
pem_name: ASR1006-PWR-AC/ASR1006-PWR-DC/ASR1013-PWR-AC/ASR1013-PWR-DC
pem_slot_num: P0-P3
hw_config: ASR-1006/ASR-1013 chassis
Reason: The Product ID read from the PEM IDPROM is not supported in this hardware configuration. It will
be allowed to continue but immediate replacement is required.
Recommended action: Remove the PEM from the chassis and replace it with a supported PEM.
If the above combinations occur, you will see the following error messages.
Unsupported ASR1000-ESP Error Message
This section describes what happens when a Cisco ASR1000-ESP40 is present when the router is booting or
inserted at a later time into the Cisco ASR 1000 Router and provides the error message and explanation as to
why this occurred.
Error message
The ASR1000-ESP40 card is disabled and the following error message displays at the console.
Error message
%CMRP-3-UNSUPPORTED_FRU: [chars] in slot [chars] is not supported with [chars] and so it
Cisco ASR 1000 Series Router Hardware Installation Guide
32
Cisco ASR 1000 Series Routers Component Overview
Cisco ASR 1000 Series Hardware Configuration Combinations

Table of Contents

Other manuals for Cisco ASR 1001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 1001 and is the answer not in the manual?

Cisco ASR 1001 Specifications

General IconGeneral
Ethernet LANYes
Cabling technology10/100/1000Base-T(X)
Networking standards-
Ethernet LAN data rates10, 100, 1000 Mbit/s
Ethernet interface typeGigabit Ethernet
USB ports quantity1
Ethernet LAN (RJ-45) ports4
VPN tunnels quantity8000
Product colorGray
Rack capacity1U
AC input voltage85 - 264 V
Power source typeAC
AC input frequency50 - 60 Hz
Power consumption (typical)250 W
SafetyUL60950-1 CSA, C22.2 No. 60950-1-03, EN 60950-1, IEC 60950-1, AS/NZS 60950.1
CertificationFCC 47CFR15 Class A AS/NZS CISPR 22 CISPR 22 Class A EN55022 Class A ICES-003 Class A VCCI Class A CNS-13438 Class A EN61000-3-2 EN61000-3-3
Internal memory8192 MB
Operating altitude0 - 3048 m
Storage temperature (T-T)0 - 50 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)5 - 90 %
Weight and Dimensions IconWeight and Dimensions
Depth461.5 mm
Width439.42 mm
Height43.43 mm
Weight11350 g