The following table lists the Cisco ASR 1000 Series Route Processor LEDs and behavior.
Table 10: Cisco ASR 1000 Series Route Processor LEDs
Behavior Description
Color —State
LEDLED Label
All power requirements
are within specification
Solid greenPowerPWR
Off, the router is in
standby mode.
Off
—
Cisco IOS software has
booted.
Solid greenSystem statusSTAT
ROMMON has
successfully loaded.
Yellow
—
System failure or during
boot process.
Red
—
Lit when the Cisco ASR
1000 Series RP is active.
GreenActiveACTV
Lit when the Cisco ASR
1000 Series RP is the
standby processor.
YellowStandbySTBY
Critical alarm indicator or
during boot process. An
example: the ambient air
temperature is above 60ºC
and will begin shutdown
in 5 minutes.
Solid RedCriticalCRIT
Major alarm indicator.
For example: Ambient air
temperature is beyond
short term operating range
of 55ºC. System will shut
down above 60ºC.
Solid RedMajorMAJ
Cisco ASR 1000 Series Router Hardware Installation Guide
40
Cisco ASR 1000 Series Routers Component Overview
Cisco ASR 1000 Series Route Processor Differences