CDM-625A Advanced Satellite Modem MN-CDM625A
Serial-based Remote Product Management Revision 4
8–42
Parameter
Command
(Instruction
& Qualifier)
Length of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
Port
Monitoring
Destination
Port
PMD=
1 byte
Command or Query.
Used to set the port monitoring destination (capturing) port in the form x, where:
1=port 1
2=port 2
3=port 3
4=port 4
EXAMPLE: <0/PMD=1
Source port and destination port must be different.
PMD=
PMD?
PMD*
PMD#
PMD?
PMD=x
(see Description of
Arguments)
Port
Monitoring
Direction
PMI=
1 byte
Command or Query.
Sets or returns the port monitoring direction in the form x, where:
1=Ingress (Rx)
2=Egress (Tx)
3=Both (Rx and Tx)
EXAMPLE: <0/PMI=1
PMI=
PMI?
PMI*
PMI#
PMI?
PMI=x
(see Description of
Arguments)
Simple
Network
Time Protocol
Time Zone
TPZ=
2 bytes
Command or Query.
Sets or returns the SNTP time zone in the form xx, where:
TPZ=
TPZ?
TPZ *
TPZ #
TPZ?
TPZ =xx
(see Description of
Arguments)
00 = GMT-12:00
01 = GMT-11:00
02 = GMT-10:00
03 = GMT-09:00
04 = GMT-08:00
05 = GMT-07:00
06 = GMT-06:00
07 = GMT-05:00
08 = GMT-04:30
09 = GMT-04:00
10 = GMT-03:30
11 = GMT-03:00
12 = GMT-02:30
13 = GMT-02:00
14 = GMT-0
15 = GMT
16 = GMT+01:00
17 = GMT+02:00
18 = GMT+03:00
19 = GMT+03:30
20 = GMT+04:00
21 = GMT+04:30
22 = GMT+05:00
23 = GMT+05:30
24 = GMT+05:45
25 = GMT+06:00
26 = GMT+06:30
27 = GMT+07:00
28 = GMT+08:00
29 = GMT+09:00
30 = GMT+09:30
31 = GMT+10:00
32 = GMT+10:30
33 = GMT+11:00
34 = GMT+12:00
35 = GMT+13:00
36 = GMT+14:00
EXAMPLE: <0/TPZ=05