CDM-625A Advanced Satellite Modem MN-CDM625A
CDM-625A ODU (Transceiver, BUC, LNB) Operation Revision 4
1050
Recalibrate LNA Current
Click to recalibrate the LNA Current.
Redundancy Box Mode
Select Automatic or Manual, and then click [Submit].
ODU Date & Time
Enter a date in the form DD/MM/YY (where DD = day [01 to 31], MM = month [01 to 12],
and YY = year [00 to 99]).
Enter a time using HH:MM:SS format (where HH = hour [00 to 23], MM = minutes [00 to 59],
and SS = seconds [00 to 59]).
Click [Enter Date/Time] once you enter the desired date and time in this section.
ODU Stored Events
This section includes a scrollable window, which provides a visual record of the ODU stored
events.
Unread EventsDisplays the total number of unread stored events in the scrollable events
window. As stored event groups are displayed, this number decrements accordingly.
Read Next Five EventsClick to buffer the next group of five stored events into the
scrollable events window.
Clear Stored EventsClick to wipe clean the stored events log.
Initialize Events PointerClick to reset the log’s internal pointer.
Click [Submit] to save.