Reviewing Port Status
Enterasys G-Series CLI Reference 4-3
Example
Thisexampleshowshowtoconfigureportge.2.1intheG3G‐24SFPmoduletooperatewitha
100BASE‐FXtransceiverinstalled.First,themoduleisverifiedaspresentinSlot2,andtheport
statusisshownasoperatingasa1000BASE‐SXport.Afterthe1‐Gigabittransceiverisreplaced
withthea100Mbpstransceiver,theportisconfiguredappropriatelyandthenewsettingsare
verified.
G3(su)->show version
Slot Status Ports Model Serial Number Hw Version
---- -------- ----- ---------- ------------- --------------
1 Present 24 G3G170-24 0011223302 BCM56514 REV 1
2 Present 24 G3G-24SFP H03611239 BCM56512 REV 1
3
4
G3(su)->show port advertise ge.2.1
ge.2.1 capability advertised remote
-------------------------------------------------
10BASE-T no no no
10BASE-TFD no no no
100BASE-TX no no no
100BASE-TXFD yes no no
1000BASE-T no no no
1000BASE-TFD yes yes no
pause yes yes no
G3(su)->show port status ge.2.1
Alias Oper Admin Speed
Port (truncated) Status Status (bps) Duplex Type
--------- ------------ ------- ------- --------- ------- ------------
ge.2.1 Down Up N/A N/A 1000BASE-SX
G3(su)->set port negotiation ge.2.1 disable
G3(su)->set port advertise ge.2.1 100txfd
G3(su)->set port speed ge.2.1 100
G3(su)->set port duplex ge.2.1 full
G3(su)->show port status ge.2.1
Alias Oper Admin Speed
Port (truncated) Status Status (bps) Duplex Type
--------- ------------ ------- ------- --------- ------- ------------
ge.2.1 Down Up 100.0M full 100BASE-FX
Formoreinformation,refertothecommandsinthischapterandtoyourG‐Serieshardware
installationdocumentation.
Reviewing Port Status
Purpose
Todisplayoperatingstatus,duplexmode,speed,porttype,andstatisticalinformationabout
trafficreceivedandtransmittedthroughoneorallswitchportsonthedevice.