clear rmon alarm
Enterasys G-Series CLI Reference 12-11
Parameters
Defaults
None.
Mode
Switchcommand,read‐write.
Usage
AnRMONalarmentrycanbecreatedusingthiscommand,configuredusingthesetrmonalarm
propertiescommand(“setrmonalarmproperties”onpage 12‐9),thenenabledusingthis
command.AnRMONalarmentrycanbecreatedandconfiguredatthesametimebyspecifying
anunusedindexwiththe
setrmonalarmpropertiescommand.
Example
ThisexampleshowshowtoenableRMONalarmentry3:
G3(rw)->set rmon alarm status 3 enable
clear rmon alarm
UsethiscommandtodeleteanRMONalarmentry.
Syntax
clear rmon alarm index
Parameters
Defaults
None.
Mode
Switchcommand,read‐write.
Example
ThisexampleshowshowtoclearRMONalarmentry1:
G3(rw)->clear rmon alarm 1
index Specifiesanindexnumberforthisentry.Maximumnumberorentriesis
50.Maximumvalueis65535.
enable Enablesthisalarmentry.
index Specifiestheindexnumberofentrytobecleared.