Filter Group Commands
Enterasys G-Series CLI Reference 12-15
Defaults
None.
Mode
Switchcommand,read‐write.
Example
ThisexampleshowshowtoclearRMONevent1:
G3(rw)->clear rmon event 1
Filter Group Commands
Thepacketcaptureandfilterfunctionisdisabledbydefault.Onlyoneinterfacecanbeconfigured
forcapturingandfilteringatatime.
Whenpacketcaptureisenabledonaninterface,theG‐Seriesswitchwillcapture100framesas
closetosequentiallyaspossible.These100frameswillbeplaced
intoabufferforinspection.If
thereisdatainthebufferwhenthefunctionisstarted,thebufferwillbeoverwritten.Once100
frameshavebeencaptured,thecapturewillstop.Filteringwillbeperformedontheframes
capturedinthebuffer.Therefore,onlyasubsetoftheframes
capturedwillbeavailablefor
display.
Onechannelatatimecanbesupported,withuptothreefilters.Configuredchannel,filter , and
buffercontrolinformationwillbesavedacrossresets,butcapturedframeswithinthebufferwill
notbesaved.
Thisfunctioncannotbeusedconcurrentlywithportmirroring.Thesystem
willchecktoprevent
concurrentlyenablingbothfunctions,andawarningwillbegeneratedintheCLIifattempted.
Commands
Note: Packet capture is sampling only and does not guarantee receipt of back to back packets.
For information about... Refer to page...
show rmon channel 12-16
set rmon channel 12-16
clear rmon channel 12-17
show rmon filter 12-17
set rmon filter 12-18
clear rmon filter 12-19