set width
2-24 Basic Configuration
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtosetthesystemcontactstring:
G3(su)->set system contact “Joe Smith”
set width
Usethiscommand tosetthenumberofcolumnsfor theterminalconnectedtotheswitch’sconsole
port.
Syntax
set width screenwidth [default]
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
ThenumberofrowsofCLIoutputdisplayedissetusingthesetlengthcommandasdescribedin
setlengthonpage224.
Example
Thisexampleshowshowtosettheterminalcolumnsto50:
G3(su)->set width 50
set length
UsethiscommandtosetthenumberoflinestheCLIwilldisplay.Thiscommandispersistent
(writtentoNVRAM).
Syntax
set length screenlength
screenwidth Setsthenumberofterminalcolumns.Validvaluesare50to150.
default (Optional)Makesthissettingpersistentforallfuturesessions(writtento
NVRAM).

Table of Contents