set snmp notifyfilter
Enterasys G-Series CLI Reference 5-33
Defaults
Ifnoparametersarespecified,allnotifyfilterinformationwillbedisplayed.
Mode
Switchcommand,readonly.
Usage
SeeAboutSNMPNotifyFiltersonpage 528formoreinformationaboutnotifyfilters.
Example
ThisexampleshowshowtodisplaySNMPnotifyfilterinformation.Inthiscase,thenotifyprofile
“pilot1”insubtree 1.3.6willnotreceiveSNMPnotificationmessages:
G3(su)->show snmp notifyfilter
--- SNMP notifyFilter information ---
Profile = pilot1
Subtree = 1.3.6
Filter type = included
Storage type = nonVolatile
Row status = active
set snmp notifyfilter
UsethiscommandtocreateanSNMPnotifyfilterconfiguration.Thisidentifieswhich
managementtargetsshouldNOTreceive notificationmessages,whichisusefulforfinetuningthe
amountofSNMPtrafficgenerated.
Syntax
set snmp notifyfilter profile subtree oid-or-mibobject [mask mask] [included |
excluded] [volatile | nonvolatile]
Parameters
volatile|
nonvolatile|read
only
(Optional)Displaysnotifyfilterentriesofaspecificstoragetype.
profile SpecifiesanSNMPfilternotifyname.
subtreeoidor
mibobject
SpecifiesaMIBsubtreeIDtargetforthefilter.
maskmask (Optional)Appliesasubtreemask.
included|
excluded
(Optional)Specifiesthatsubtreeisincludedorexcluded.
volatile|
nonvolatile
(Optional)Specifiesastoragetype.

Table of Contents