EasyManua.ls Logo

Enterasys G3G170-24 - Ipv6 Nd Ra-Interval; Ipv6 Nd Ra-Lifetime

Enterasys G3G170-24
679 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ipv6 nd ra-interval
18-16 IPv6 Configuration
Usage
Whenthevalueofthe“otherstatefulconfiguration”flagistrue,endnodesshouldusestateful
autoconfiguration(DHCPv6)toobtainadditionalinformation(excludingaddresses).Whenthe
valueisfalse,endnodesdonot.RefertoRFC2462,“IPv6StatelessAddressAutoconfiguration,”
formoreinformation.
Usethenoformofthiscommand
toresettheflagtofalse.
Example
Thisexamplesetstheotherstatefulconfigurationflagtotru e.
G3(su)->router(Config-if(Vlan 1))# ipv6 nd other-config-flag
ipv6 nd ra-interval
Thiscommandsetsthetransmissionintervalbetweenrouteradvertisements.
Syntax
ipv6 nd ra-interval sec
no ipv6 nd ra-interval
Parameters
Defaults
600seconds.
Mode
Routerinterfaceconfiguration:G3(su)>router(Configif(Vlan1))#
Usage
Thenoformofthiscommandresetstheintervalvaluetothedefaultof600seconds.
Example
Thisexamplesetstherouteradvertisementtransmissionintervalto120seconds.
G3(su)->router(Config-if(Vlan 1))# ipv6 nd ra-interval 120
ipv6 nd ra-lifetime
Thiscommandsetsthevalue,inseconds,thatisplacedintheRouterLifetimefieldofrouter
advertisementssentfromthisinterface.
Syntax
ipv6 nd ra-lifetime sec | 0
no ipv6 nd ra-lifetime
sec Specifiesthevalueinsecondsoftherouteradvertisementtransmission
interval.Thevaluecanrangefrom4to1800seconds.

Table of Contents

Related product manuals