18. Common Reference System
18-9
18.5 Mode of Workstations
The system is designed so that information and operations are shared among workstations. Sharing requires that the
access server be running in the specified workstation. (This is an installation parameter. See the Installation
Manual.) The access server requires that the workstation be designated as multi workstation.
If something fails in a workstation or in the LAN connecting the workstations that prevents multi workstation
operations, it is possible to switch the mode to single workstation. If the mode of a workstation that is defined in the
installation parameters for the access server is set as a single workstation, the access server is stopped and the
workstation continues as if they are separate individual ECDIS systems.
Note: When the mode is single workstation, no data are harmonised nor are information of operator selection shared
between workstations.
18.5.1 How to change mode to single or multi workstation
To change sensor source, do the following:
1. On the workstation for which you want to set
sensor source, put the cursor below the Lost
TGT alarm indication, confirm that Initial
Settings is shown in the mouse functions
area then push the right mouse button.
2. Check Mode and select appropriate
workstation from the List box.
In this example, the workstation mode was
changed from multi to single.
The selection Single workstation disables
selections of usage rights and sensor source and
stops the access server operations on the
workstation. In the single workstation mode, the
indication SINGLE appears at the lower right
hand corner in yellow.
Single
NM
NM