8.4.4 Failed SENC conversions window
If the system is unable to convert ENC into SENC without error or failure, the Failed SENC conversions window
appears with a list of failed ENCs.
"Errors" in the Status column means that the system detected minor or major errors in the conversion of the ENC
into the SENC. Use the Conv. History and Cell Status buttons to see if the error was minor or major. Major errors
are indicated as NON ENC in the Conv. History. In the example below the status of errors together with NON ENC
in the Conv History clearly indicate that this chart is not up-to-date and thus it does not fulfil SOLAS requirements.
Get the latest edition of this chart from the publisher immediately.
"Failed" means that the system completely failed to convert the ENC into the SENC and thus the ENC cannot be
used as it does not fulfil SOLAS requirements. Get the latest edition of this chart from the publisher immediately.
The Conv. History button is used to display
the conversion log. The conversion log shows
the status of converted ENCs. See section
8.4.5 "SENC conversion history log".
Click the Cell Status button, and a Chart Cell Status window appears.
Then you can click the Conv Log button to view a detailed description of errors and failures detected during SENC
conversion (see the example below).