Appendix 5: C-MAP CM-93/2 Charts
AP-75
3. In the Load Selector field, you can select how to pick desired charts from the list:
Name: ECDIS will display chart names on graphical presentation if selected.
Permit: ECDIS will highlight the charts which are available in the CD-ROM and for which you have
permits.
RENC Canceled Charts: ECDIS will display charts on display, which are canceled on RENC and normally
on CD-ROM.
Group: If you have predefined a group of charts, ECDIS will highlight those charts in the group, which are
available in the CD-ROM.
Manual Selection: You can highlight desired charts from the list.
Missing only: Loads and displays on graphical presentation only charts and their updates, which are not
already loaded into the ECDIS.
4. View CD-ROM Publisher Notes button is used to view important notices published by chart producer, View
CD-ROM content Summary button is used to list charts available on CD-ROM and Load History and Conv.
History button check what is loaded and converted from the CD-ROM. The Remove button is used to remove
the CD-ROM catalogue permanently from the ECDIS.
5. The Edit Group button is used to create and modify group. For more information, see A5.2.7 "Grouping S57
chart cells".
6. The Load button is used to start loading.
Note: The system can make conversion into the SENC and set the "Display Until" date automatically. This is the
recommended way. For how to do this, see section 8.4.2 "How to get automatic SENC conversion and display until
date".
How to display CD-ROM contents summary
You can view the Summary of the contents of the CD-ROM. It contains information about charts you are going to
load.
1. Spin the scrollwheel to show Menu/Info/Chart Menu in the mouse functions area then push the right mouse
button.
2. Select Load and Update Charts from the menu and "from CD-ROM" from the sub menu. Click the Load button.
3. Click the View CD-ROM content Summary button.
A viewer shows information about the selected "CD-ROM".
Each row contains:
Cell ID: Name of the chart
Edition: Edition number of the chart
Base: Included update number and issue date of Base cell of the chart
First Update: Update number and issue date of the first update included
Last Update: Update number and issue date of the last update included
4. If you want to make a hard copy of the Publisher Notes, click the Print Text button.
5. To close this window, click the X in the upper right corner.