Table 5-1 Software Options at EC300/EC310 (BT15/BT16)
BT15
(EC300)
BT16
(EC310)
HCat # Software Option Description
VE6
VE8
VE10
VE6
VE8
VE10
H48681FM Advanced 4D (incl. Real time 4D, RT-4D Biopsy,
VCI "Basic" and TUI),
Advanced 4D
X X X X X X
H48691KK HD
live HDlive
1) S* - 1) S* -
H48691XZ HD
live
Silhouette
HDlive Silhouette
- 1) S* - 1) S*
H48681FN VOCAL II
VOCAL II - Virtual Organ Computer-aided Analysis
1) 1) 1) 1) 1) 1)
H48681FP Advanced VCI (VCI OmniView)
Advanced VCI
2) 2) 2) 2) 2) 2)
H48681FT Contrast Imaging
Coded Contrast Imaging
X X X X X X
H48681FW Sono VCAD
heart SonoVCAD heart - Computer Assisted Heart
Diagnosis
1) - - 1) - -
H48681FX SonoAVC
SonoAVC - Sono Automated Volume Count
1) 1) 1) 1) 1) 1)
H48681FY SonoVCAD
labor SonoVCAD labor
1) 1) 1) 1) 1) 1)
H48681FZ Anatomical M-Mode
Anatomical M-Mode (AMM)
X X X X X X
H48681GD Advanced STIC (incl. Basic STIC, STIC M-Mode
and STIC
flow
) + SonoVCAD
heart
Advanced STIC (Spatio-Temporal Image
Correlation)
- 2) 2) - 2) 2)
H48681FS STIC "Basic"
STIC “Basic” (Spatio-Temporal Image Correlation)
2) - - 2) - -
H48681GB Elastography (incl. Elastography Analysis)
Elastography
X X X X X X
H48681TK V-SRI
V-SRI Advanced - Speckle Reduction Imaging
- - 3) - - 3)
H48691YA eM6C - E4D Activation (incl.
e
STIC)
eM6C - E4D Activation (Advanced Features for
Electronic 4D Matrix-Probe)
- - X - - X
H48691NZ CW-Doppler
CW - Continuous Wave Doppler
X X X X X X
H48691XF SW DVR
SW DVR - Software Digital Video Recording
X X X X X X
H48691KG RLS Option Russian Language Support X X X X X X
Legend:
X Optional Feature (separately purchasable)
- not available
S Standard Feature, S* can be used in 3D-Mode, but for 4D-Modes the option “Advanced 4D” has to be active as well
1) this 3D/4D option can be used in 3D-Mode, but for 4D-Modes the option “Advanced 4D” has to be active as well
2) this 4D option is only available if the option “Advanced” 4D is active
as well
3) only with probe RM6C, RIC5-9-D, RIC6-12-D
4) Optional Feature, requires software version EC320 Ext.4 (17.0.4) or higher
R restricted, not yet released in all countries
Components and Functions (Theory)
Voluson E-Series Service Manual
5539550APB Revision 6
5-13

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Voluson E Series and is the answer not in the manual?

GE Voluson E Series Specifications

General IconGeneral
BrandGE
ModelVoluson E Series
CategoryMedical Equipment
LanguageEnglish

Related product manuals