Chapter 10
Care and Maintenance
This chapter describes Care and Maintenance on the Voluson E-Series system
and its peripherals. These procedures are intended to maintain the quality of the
Voluson E-Series systems performance. Read this chapter completely and
familiarize yourself with the procedures before performing a task.
Content in this chapter
10.1 Why do Maintenance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-2
10.2 Maintenance Task Schedule - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-2
10.3 Tools required - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-4
10.4 System Maintenance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-5
10.5 Using a Phantom - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-9
10.6 Electrical Safety Tests - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-10
10.7 When there's too much Leakage Current... - - - - - - - - - - - - - - - - - - - - - - 10-23
10.8 Ultrasound Equipment Quality Check - - - - - - - - - - - - - - - - - - - - - - - - - - 10-24
Caution: Practice good ESD prevention.
Wear an anti–static strap when handling electronic parts and even when disconnecting/connecting
cables.
Warning
Be sure to disconnect the Voluson E-Series ultrasound system power plug and switch off the main
circuit breaker before you remove any parts. Be cautious whenever power is still on and covers are
removed.
Caution
Do not pull out or insert circuit boards while power is ON.
Caution
The system requires all covers. Do not operate the Voluson E-Series system unless all board
covers and frame panels are securely in place. The covers are required for safe operation, good
system performance and cooling purposes. When covers are removed, EMI may be present.
Caution
To ensure the mutual protection and safety of GE service personnel and our customers, all
equipment and work areas must be clean and free of any hazardous contaminants before a service
engineer starts a repair. This includes, but is not limited to, decontamination and/or sterilization,
depending on the application or use of the medical device.
Voluson E-Series Service Manual
5539550APB Revision 6
10-1