EasyManuals Logo

HP P2000 Reference Guide

HP P2000
448 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #118 background imageLoading...
Page #118 background image
118 Alphabetical list of commands
scrub vdisk
Description Analyzes specified vdisks to detect, report, and store information about disk defects. Vdisk-level
errors reported include: hard errors, media errors, and bad block replacements (BBRs). Disk-level
errors reported include: metadata read errors, SMART events during scrub, bad blocks during scrub,
and new disk defects during scrub.
For RAID 3, 5, 6, and 50, scrub checks all parity blocks to find data-parity mismatches. For RAID 1
and 10, scrub compares the primary and secondary disks to find data inconsistencies. For NRAID
and RAID 0, scrub checks for media errors.
A scrub can last over an hour, depending on vdisk size, utility priority, and amount of I/O activity.
However, a “foreground” scrub performed with this command is typically faster than a background
scrub enabled with the set job-parameters command. You can use a vdisk while it is being scrubbed.
When the scrub is complete, an event with code 207 is logged that specifies whether errors were
found. For details, see the Event Descriptions Reference Guide.
Syntax
scrub vdisk vdisks
Parameters vdisks
Names or serial numbers of the vdisks to scrub. For vdisk syntax, see Command syntax on page 21.
Example Scrub the disks in vdisk vd1:
# scrub vdisk vd1
Info: Scrub was started on vdisk vd1.
See also abort scrub
set advanced-settings
set job-parameters
show vdisks

Table of Contents

Other manuals for HP P2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 and is the answer not in the manual?

HP P2000 Specifications

General IconGeneral
Drive SupportSAS
ControllerDual Controller options available
Host Interface6Gb SAS, 8Gb FC, 1Gb iSCSI
RAID LevelsRAID 0, 1, 5, 6, 10
Storage TypeSSD
Hot-swappable ComponentsDrives, controllers, power supplies, fans
Dimensions8.9 x 44.8 x 63.5 cm (3.5 x 17.6 x 25 inches)
Drive BaysUp to 12 LFF or 24 SFF drive bays per enclosure

Related product manuals