HP P2000 G3 MSA System CLI Reference Guide 239
show sensor-status
Description Shows temperatures and voltages of controller modules and power supplies. These values are
reported by environmental sensors in each controller module and power supply (PSU). In the output,
Ctlr and IOM signify a controller module.
Normal and error ranges for temperature and voltage are specified in the user guide.
Syntax
show sensor-status
Output Sensor Name
Sensor name and location.
Value
• For a sensor, its value.
• For overall unit status, one of the status values below.
Status
• OK: The sensor is present and detects no error condition.
• Warning: The sensor detected a non-critical error condition. Temperature, voltage, or current is
between the warning and critical thresholds.
• Error: The sensor detected a critical error condition. Temperature, voltage, or current exceeds
the critical threshold.
• Unavailable: The sensor is present with no known errors, but has not been turned on or set
into operation because it is initializing. This typically occurs during controller startup.
• Unrecoverable: The enclosure management processor (EMP) cannot communicate with the
sensor.
• Unknown: The sensor is present but status is not available.
• Not Installed: The sensor is not present.
• Unsupported: Status detection is not implemented.
• Other: Status is not available for some other reason.
Example Show temperature and voltage status for the controllers and power supplies:
# show sensor-status
Sensor Name Value Status
----------------------------------------------------
On-Board Temperature 1-Ctlr A 55 C OK
On-Board Temperature 1-Ctlr B 54 C OK
On-Board Temperature 2-Ctlr A 76 C OK
On-Board Temperature 2-Ctlr B 69 C OK
On-Board Temperature 3-Ctlr A 53 C OK
On-Board Temperature 3-Ctlr B 55 C OK
Disk Controller Temp-Ctlr A 31 C OK
Disk Controller Temp-Ctlr B 30 C OK
Memory Controller Temp-Ctlr A 71 C OK
Memory Controller Temp-Ctlr B 76 C OK
Capacitor Pack Voltage-Ctlr A 8.20 OK
Capacitor Pack Voltage-Ctlr B 8.12 OK
Capacitor Cell 1 Voltage-Ctlr A 2.04 OK
Capacitor Cell 1 Voltage-Ctlr B 2.02 OK
Capacitor Cell 2 Voltage-Ctlr A 2.04 OK
Capacitor Cell 2 Voltage-Ctlr B 2.08 OK
Capacitor Cell 3 Voltage-Ctlr A 2.03 OK
Capacitor Cell 3 Voltage-Ctlr B 2.02 OK
Capacitor Cell 4 Voltage-Ctlr A 2.08 OK
Capacitor Cell 4 Voltage-Ctlr B 2.00 OK

Table of Contents

Other manuals for HP P2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 and is the answer not in the manual?

HP P2000 Specifications

General IconGeneral
Drive SupportSAS
ControllerDual Controller options available
Host Interface6Gb SAS, 8Gb FC, 1Gb iSCSI
RAID LevelsRAID 0, 1, 5, 6, 10
Storage TypeSSD
Hot-swappable ComponentsDrives, controllers, power supplies, fans
Dimensions8.9 x 44.8 x 63.5 cm (3.5 x 17.6 x 25 inches)
Drive BaysUp to 12 LFF or 24 SFF drive bays per enclosure