HP P2000 G3 MSA System CLI Reference Guide 305
controller-cache-parameters
Properties
Example
# show cache-parameters
...
<OBJECT basetype="controller-cache-parameters" name="controller-b-cache-parameters"
oid="3" format="pairs">
<PROPERTY name="durable-id" type="string">cache-params-b</PROPERTY>
<PROPERTY name="controller-id" type="string">B</PROPERTY>
<PROPERTY name="controller-id-numeric" type="string">0</PROPERTY>
<PROPERTY name="name" type="string">Controller B Cache Parameters</PROPERTY>
<PROPERTY name="write-back-status" type="string">Enabled</PROPERTY>
Table 17 controller-cache-parameters properties
Name Type Description
durable-id string • cache-params-a: Cache parameters for controller A.
• cache-params-b: Cache parameters for controller B.
controller-id string • A: Controller A.
• B: Controller B.
controller-id-
numeric
string Numeric equivalents for controller-id values.
• 0: B
• 1: A
name string • Controller A Cache Parameters
• Controller B Cache Parameters
write-back-
status
string The current, system-wide cache policy as determined by auto-write-through
(AWT) logic. This value is not settable by users. If an AWT trigger condition
(such as a CompactFlash failure) is met, the cache policy for all volumes
changes to write-through, overriding the volume-specific settings. When the
problem is corrected, the cache policy reverts to the value configured for each
individual volume.
• Enabled: Write-back. This is the normal state.
• Disabled: Write-through.
• Not up: The controller is not up.
write-back-
status-numeric
string Numeric equivalents for write-back-status values.
• 0: Enabled (write-back)
• 1: Disabled (write-through)
• 2: Not up
compact-flash-
status
string • Not Installed
• Installed
• Unknown
compact-flash-
status-numeric
string Numeric equivalents for compact-flash-status values.
• 0: Not Installed
• 1: Installed
cache-flush string • Enabled: If the controller loses power, it will automatically write cache data
to the CompactFlash card. Cache flush is normally enabled, but is
temporarily disabled during controller shut down.
• Disabled: Cache flush is disabled.
cache-flush-
numeric
string Numeric equivalents for cache-flush values.
• 0: Disabled
•
1: Enabled

Table of Contents

Other manuals for HP P2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 and is the answer not in the manual?

HP P2000 Specifications

General IconGeneral
Drive SupportSAS
ControllerDual Controller options available
Host Interface6Gb SAS, 8Gb FC, 1Gb iSCSI
RAID LevelsRAID 0, 1, 5, 6, 10
Storage TypeSSD
Hot-swappable ComponentsDrives, controllers, power supplies, fans
Dimensions8.9 x 44.8 x 63.5 cm (3.5 x 17.6 x 25 inches)
Drive BaysUp to 12 LFF or 24 SFF drive bays per enclosure