HP P2000 G3 MSA System CLI Reference Guide 135
set expander-fault-isolation
Description For use by or with direction from a service technician.
By default, the Expander Controller in each I/O module performs fault-isolation analysis of SAS
expander PHY statistics. When one or more error counters for a specific PHY exceed the built-in
thresholds, the PHY is disabled to maintain storage system operation.
While troubleshooting a storage system problem, a service technician can use this command to
temporarily disable fault isolation for a specific Expander Controller in a specific enclosure.
NOTE: If fault isolation is disabled, be sure to re-enable it before placing the system back into
service. Serious problems can result if fault isolation is disabled and a PHY failure occurs.
Syntax
set expander-fault-isolation
encl enclosure-ID
controller a|b|both
enabled|disabled|on|off
Parameters encl enclosure-ID
The enclosure ID of the enclosure containing the PHY.
controller a|b|both
The I/O module containing the Expander Controller whose setting you want to change: A, B, or
both.
enabled|disabled|on|off
Whether to enable or disable PHY fault isolation.
Example Disable PHY fault isolation for Expander Controller A in an enclosure:
# set expander-fault-isolation encl 1 controller a disabled
Success: Command completed successfully. - Expander fault isolation was
disabled.
Re-enable PHY fault isolation for Expander Controller A in the same enclosure:
# set expander-fault-isolation encl 1 controller a enabled
Success: Command completed successfully. - Expander fault isolation was enabled.
See also • set expander-phy
• show enclosures
• show expander-status

Table of Contents

Other manuals for HP P2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 and is the answer not in the manual?

HP P2000 Specifications

General IconGeneral
Drive SupportSAS
ControllerDual Controller options available
Host Interface6Gb SAS, 8Gb FC, 1Gb iSCSI
RAID LevelsRAID 0, 1, 5, 6, 10
Storage TypeSSD
Hot-swappable ComponentsDrives, controllers, power supplies, fans
Dimensions8.9 x 44.8 x 63.5 cm (3.5 x 17.6 x 25 inches)
Drive BaysUp to 12 LFF or 24 SFF drive bays per enclosure