HP P2000 G3 MSA System CLI Reference Guide 337
events
Properties
Example
# show events
...
<OBJECT basetype="events" name="event" oid="2" format="packed">
<PROPERTY name="time-stamp" type="string">2010-10-28 11:58:47</PROPERTY>
<PROPERTY name="time-stamp-numeric" type="string">1288267127</PROPERTY>
<PROPERTY name="event-code" type="string">153</PROPERTY>
<PROPERTY name="event-id" type="string">A39873</PROPERTY>
<PROPERTY name="model" type="string">P2000 G3 iSCSI</PROPERTY>
<PROPERTY name="serial-number" type="string">SN</PROPERTY>
<PROPERTY name="controller" type="string">A</PROPERTY>
<PROPERTY name="controller-numeric" type="string">1</PROPERTY>
<PROPERTY name="severity" type="string">INFORMATIONAL</PROPERTY>
<PROPERTY name="severity-numeric" type="string">0</PROPERTY>
<PROPERTY name="message" type="string">The Storage Controller resumed communications
with the Management Controller.</PROPERTY>
</OBJECT>
...
Table 29 events properties
Name Type Description
time-stamp string Date and time, in the format year-month-day hour:minutes:seconds
(UTC), when this event was detected.
time-stamp-
numeric
string Unformatted time-stamp value.
event-code string Event code. For event-code descriptions, see the Event Descriptions Reference
Guide.
event-id string Event ID.
model string Controller model.
serial-number string Controller serial number.
controller string • A: Controller A.
• B: Controller B.
controller-
numeric
string Numeric equivalents for controller values.
• 0: B
• 1: A
severity string Event severity.
• CRITICAL: A failure occurred that may cause a controller to shut down.
Correct the problem immediately.
• ERROR: A failure occurred that may affect data integrity or system stability.
Correct the problem as soon as possible.
• WARNING: A problem occurred that may affect system stability but not data
integrity. Evaluate the problem and correct it if necessary.
• INFORMATIONAL: A configuration or state change occurred, or a problem
occurred that the system corrected. No action is required.
severity-
numeric
string Numeric equivalents for severity values.
• 0: INFORMATIONAL
• 1: WARNING
• 2: ERROR
• 3: CRITICAL
message string Message giving details about the event.

Table of Contents

Other manuals for HP P2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 and is the answer not in the manual?

HP P2000 Specifications

General IconGeneral
Drive SupportSAS
ControllerDual Controller options available
Host Interface6Gb SAS, 8Gb FC, 1Gb iSCSI
RAID LevelsRAID 0, 1, 5, 6, 10
Storage TypeSSD
Hot-swappable ComponentsDrives, controllers, power supplies, fans
Dimensions8.9 x 44.8 x 63.5 cm (3.5 x 17.6 x 25 inches)
Drive BaysUp to 12 LFF or 24 SFF drive bays per enclosure