HP P2000 G3 MSA System CLI Reference Guide 185
show disk-parameters
Description Shows disk settings.
Syntax
show disk-parameters
Output SMART
Shows whether SMART is enabled or disabled for all disks, or is set to detect-only, which
specifies that each new disk inserted in the system retains its current SMART setting.
Drive Write Back Cache
Shows whether write-back cache for each disk in or added to the system will be enabled or disabled
after a rescan or controller restart. Don't Modify means that each disk’s current setting will not be
modified.
Timeout Retry Maximum
Maximum number of times a timed-out I/O operation can be retried before the operation is failed.
Attempt Timeout
Number of seconds before an I/O operation is aborted and possibly retried.
Overall Timeout
Total time in seconds before an I/O operation is failed regardless of the Attempt Timeout and
Number of Retries settings.
Drive Spin Down Non-Vdisk Enable
Shows whether DSD is enabled for available disks and global spares.
Drive Spin Down Non-Vdisk Delay
Shows the number of minutes after which inactive available disks and global spares automatically
spin down. If the delay is 0, DSD is disabled.
Example Show disk settings:
# show disk-parameters
Disk Parameters
-------------
SMART: Enabled
Drive Write Back Cache: Disabled
Timeout Retry Maximum: 3
Attempt Timeout: 8
Overall Timeout: 105
Drive Spin Down Non-Vdisk Enable: Disabled
Drive Spin Down Non-Vdisk Delay: 0
Basetypes • drive-parameters
• status
See also • set disk-parameters

Table of Contents

Other manuals for HP P2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 and is the answer not in the manual?

HP P2000 Specifications

General IconGeneral
Drive SupportSAS
ControllerDual Controller options available
Host Interface6Gb SAS, 8Gb FC, 1Gb iSCSI
RAID LevelsRAID 0, 1, 5, 6, 10
Storage TypeSSD
Hot-swappable ComponentsDrives, controllers, power supplies, fans
Dimensions8.9 x 44.8 x 63.5 cm (3.5 x 17.6 x 25 inches)
Drive BaysUp to 12 LFF or 24 SFF drive bays per enclosure

Related product manuals