122 Alphabetical list of commands
set auto-write-through-trigger
Description Sets the trigger conditions that cause the controller to change the cache policy from write-back to
write-through. You can set multiple triggers. By default super-cap-failure and
auto-write-back are enabled. Alias: set awt.
When the cache mode is changed, an event is logged.
Syntax
set auto-write-through-trigger
[controller-failure enabled|disabled|on|off]
[super-cap-failure enabled|disabled|on|off]
[compact-flash-failure enabled|disabled|on|off]
[power-supply-failure enabled|disabled|on|off]
[fan-failure enabled|disabled|on|off]
[temperature-exceeded enabled|disabled|on|off]
[partner-notify enabled|disabled|on|off]
[auto-write-back enabled|disabled|on|off]
Parameters controller-failure enabled|disabled|on|off
If the cache policy is set to write-back, specify whether the policy automatically changes to
write-through when a controller fails.
super-cap-failure enabled|disabled|on|off
If the cache policy is set to write-back, specify whether the policy automatically changes to
write-through when cache backup power is not fully charged or fails.
compact-flash-failure enabled|disabled|on|off
If the cache policy is set to write-back, specify whether the policy automatically changes to
write-through when CompactFlash memory fails.
power-supply-failure enabled|disabled|on|off
If the cache policy is set to write-back, specify whether the policy automatically changes to
write-through when a power supply fails.
fan-failure enabled|disabled|on|off
If the cache policy is set to write-back, specify whether the policy automatically changes to
write-through when a fan fails.
temperature-exceeded enabled|disabled|on|off
Specify whether to force a controller shutdown if a temperature is detected that exceeds system
threshold limits.
partner-notify enabled|disabled|on|off
Specify whether to notify the partner controller that a trigger condition occurred. Enable this option
to have the partner also change to write-through mode for better data protection. Disable this option
to allow the partner to continue using its current caching mode for better performance.
auto-write-back enabled|disabled|on|off
Specify whether the cache mode automatically changes to write-back after the trigger condition is
cleared.
Example Enable the controller-failure trigger and disable the partner-notification trigger:
# set auto-write-through-trigger controller-failure enabled partner-notify
disabled
Success: Command completed successfully. - Auto-write-through-trigger parameters
were changed.
See also • show auto-write-through-trigger
• show events

Table of Contents

Other manuals for HP P2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 and is the answer not in the manual?

HP P2000 Specifications

General IconGeneral
Drive SupportSAS
ControllerDual Controller options available
Host Interface6Gb SAS, 8Gb FC, 1Gb iSCSI
RAID LevelsRAID 0, 1, 5, 6, 10
Storage TypeSSD
Hot-swappable ComponentsDrives, controllers, power supplies, fans
Dimensions8.9 x 44.8 x 63.5 cm (3.5 x 17.6 x 25 inches)
Drive BaysUp to 12 LFF or 24 SFF drive bays per enclosure