246 Alphabetical list of commands
show snmp-parameters
Description Shows SNMP settings for event notification.
Syntax
show snmp-parameters
Output SNMP Trap Notification Level
crit: Only Critical events are sent as traps
error: Error and Critical events are sent as traps
warn: Warning, Error, and Critical events are sent as traps
info: All events are sent as traps
none: No events are sent as traps and traps are disabled
SNMP Trap Host IP#
IP address of each trap host
SNMP read community
Community string for read-only access (not shown to Monitor users)
SNMP write community
Community string for write access (not shown to Monitor users)
Example Show SNMP notification settings:
# show snmp-parameters
SNMP Trap Notification Level: crit
SNMP Trap Host IP1: 172.22.4.171
SNMP Trap Host IP2: 0.0.0.0
SNMP Trap Host IP3: 0.0.0.0
SNMP read community: public
SNMP write community: private