HP P2000 G3 MSA System CLI Reference Guide 61
create vdisk
Description Creates a vdisk using the specified RAID level, disks, and spares. All disks used in a vdisk and its
spares must be either SAS or SATA; mixing disk types is not supported.
For each RAID level, the minimum and maximum numbers of disks supported are:
• NRAID: 1
• RAID 0: 2–16
• RAID 1: 2
• RAID 3: 3–16
• RAID 5: 3–16
• RAID 6: 4–16
• RAID 10: 4–16
• RAID 50: 6–32
For best practices for creating vdisks, see the SMU reference guide.
Syntax
create vdisk
level nraid|raid0|r0|raid1|r1|raid3|r3|raid5|r5|raid6|r6|raid10|r10
|raid50|r50
disks disks
[assigned-to a|b|auto]
[spare disks]
[chunk-size 16k|32k|64k]
[mode online|offline]
name
Parameters level nraid|raid0|r0|raid1|r1|raid3|r3|raid5|r5|raid6|r6|raid10|r10
|raid50|r50
Specifies the RAID level.
disks disks
IDs of the disks to include in the vdisk. RAID 10 requires a minimum of two RAID-1 sub-vdisks each
having two disks. RAID 50 requires a minimum of two RAID-5 sub-vdisks each having three disks.
For disk syntax, see Command syntax on page 21.
assigned-to a|b|auto
Optional. For a system operating in Active-Active ULP mode, this specifies the controller to own the
vdisk. To let the system automatically load-balance vdisks between controllers, use auto or omit this
parameter. In Single Controller mode, this parameter is ignored; the system automatically
load-balances vdisks in anticipation of the insertion of a second controller in the future.
spare disks
Optional. IDs of 1–4 dedicated spares to assign to a RAID 1, 3, 5, 6, 10, or 50 vdisk. For disk
syntax, see Command syntax on page 21.
chunk-size 16k|32k|64k
Optional. The amount of contiguous data, in KB, that is written to a vdisk member before moving to
the next member of the vdisk. For RAID 50, this option sets the chunk size of each RAID-5 subvdisk.
The chunk size of the RAID-50 vdisk is calculated as: configured-chunk-size x (subvdisk-members - 1).
For NRAID and RAID 1, chunk-size has no meaning and is therefore not applicable. The default
and maximum size is 64k.
mode online|offline
Optional. Specifies whether the vdisk is initialized online or offline.
• online: Enables you to use the vdisk immediately after creating it while it is initializing.
Because online uses the verify method to create the vdisk, it takes longer to complete initializing
than offline. Online initialization is fault-tolerant. This option is the default.
• offline: You must wait for the vdisk initialization process to finish before using the vdisk;
however, offline takes less time to complete initializing than online.

Table of Contents

Other manuals for HP P2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 and is the answer not in the manual?

HP P2000 Specifications

General IconGeneral
Drive SupportSAS
ControllerDual Controller options available
Host Interface6Gb SAS, 8Gb FC, 1Gb iSCSI
RAID LevelsRAID 0, 1, 5, 6, 10
Storage TypeSSD
Hot-swappable ComponentsDrives, controllers, power supplies, fans
Dimensions8.9 x 44.8 x 63.5 cm (3.5 x 17.6 x 25 inches)
Drive BaysUp to 12 LFF or 24 SFF drive bays per enclosure