HP P2000 G3 MSA System CLI Reference Guide 131
set debug-log-parameters
Description For use by or with direction from a service technician.
Sets the types of debug messages to include in the Storage Controller debug log.
Syntax
set debug-log-parameters message-type+|- [...]
Parameters message-type+|-
One of the following message types, followed by a plus (+) to enable or a minus (-) to disable
inclusion in the log:
awt: Auto-write-through cache triggers debug messages
bkcfg: Internal configuration debug messages
cache: Cache debug messages
capi: Internal Configuration API debug messages
capi2: Internal Configuration API tracing debug messages
disk: Disk interface debug messages
dms: Snapshot feature debug messages
emp: Enclosure Management Processor debug messages
fo: Failover/recovery debug messages
fruid: FRU ID debug messages
hb: Not used
host: Host interface debug messages
init: Not used
ioa: I/O interface driver debug messages (standard)
iob: I/O interface driver debug messages (resource counts)
ioc: I/O interface driver debug messages (upper layer, verbose)
iod: I/O interface driver debug messages (lower layer, verbose)
mem: Internal memory debug messages
misc: Internal debug messages
msg: Inter-controller message debug messages
mui: Internal service interface debug messages
ps: Not used
raid: RAID debug messages
rcm: Removable-component manager debug messages
res2: Internal debug messages
resmgr: Reservation Manager debug messages
Example Include RAID and cache messages, exclude EMP messages, and leave other message types
unchanged:
# set debug-log-parameters raid+ cache+ emp-
Success: Command completed successfully. - Debug-log parameters were changed.
See also show debug-log-parameters