HP P2000 G3 MSA System CLI Reference Guide 285
volumecopy
Description Copies a standard, master, or snapshot volume to a new standard volume. The destination volume
you specify must be in a vdisk owned by the same controller as the source volume. If the source
volume is a snapshot, you can choose whether to include its modified data (data written to the
snapshot since it was created). The destination volume is completely independent of the source
volume.
The first time a volume copy is created of a standard volume, the volume is converted to a master
volume and a snap pool is created in the volume’s vdisk. The snap pool’s size is either 20% of the
volume size or the minimum snap-pool size, whichever is larger. Before creating or scheduling
copies, verify that the vdisk has enough free space to contain the snap pool.
Before copying a master volume, verify that the snap-pool has space for a transient snapshot, which
is used to track changes to the master volume while the copy is in progress.
For a master volume, the volume copy creates a transient snapshot, copies the data from the
snapshot, and deletes the snapshot when the copy is complete. For a snapshot, the volume copy is
performed directly from the source; this source data may change if modified data is to be included in
the copy and the snapshot is mounted/presented/mapped and I/O is occurring to it.
To ensure the integrity of a copy of a master volume, unmount/unpresent/unmap the volume or at
minimum perform a system cache flush and refrain from writing to the volume. Since the system
cache flush is not natively supported on all operating systems, it is recommended to
unmount/unpresent/unmap temporarily. The volume copy is for all data on the disk at the time of the
request, so if there is data in the operating-system cache, that will not be copied over.
Unmounting/unpresenting/unmapping the volume forces the cache flush from the operating system.
After the volume copy has started, it is safe to remount/re-present/remap the volume and/or resume
I/O.
To ensure the integrity of a copy of a snapshot with modified data, unmount/unpresent/unmap the
snapshot or perform a system cache flush. The snapshot will not be available for read or write access
until the volume copy is complete. If modified write data is not to be included in the copy, then you
may safely leave the snapshot mounted/presented/mapped. During a volume copy using snapshot
modified data, the system takes the snapshot offline.
While the copy operation is in progress, the destination volume type is shown as standard*; when
complete, it changes to standard. To see the volume copy’s progress use the show
volumecopy-status command.
Syntax
volumecopy
source-volume source-volume
dest-vdisk vdisk
[modified-snapshot yes|no]
[prompt yes|no|expert]
destination-volume
Parameters source-volume source-volume
Name or serial number of the volume or snapshot to copy. For volume syntax, see Command syntax
on page 21.
dest-vdisk vdisk
Name or serial number of the destination vdisk. For vdisk syntax, see Command syntax on page 21.
modified-snapshot yes|no
Optional. Specifies whether to include or exclude modified write data from the snapshot in the copy.
This parameter applies only when the source volume is a snapshot.
• yes: Include modified snapshot data.
• no: Exclude modified snapshot data.
If this parameter is omitted for a snapshot, modified snapshot data is excluded.

Table of Contents

Other manuals for HP P2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 and is the answer not in the manual?

HP P2000 Specifications

General IconGeneral
Drive SupportSAS
ControllerDual Controller options available
Host Interface6Gb SAS, 8Gb FC, 1Gb iSCSI
RAID LevelsRAID 0, 1, 5, 6, 10
Storage TypeSSD
Hot-swappable ComponentsDrives, controllers, power supplies, fans
Dimensions8.9 x 44.8 x 63.5 cm (3.5 x 17.6 x 25 inches)
Drive BaysUp to 12 LFF or 24 SFF drive bays per enclosure