EasyManuals Logo

HP P2000 Reference Guide

HP P2000
448 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #140 background imageLoading...
Page #140 background image
140 Alphabetical list of commands
On a system with FC ports, set the link speed to 4 Gbit/sec for ports A1 and B1; set controller A
ports to request loop ID 5 and controller B ports to request loop ID 32; and suppress the confirmation
prompt:
# set host-parameters speed 4g ports a1,b1 fibre-loop-id 5,32 noprompt
Info: Changes to FC loop ids will not take effect until the affected Storage
Controller is restarted.
Success: Command completed successfully. - The host parameters were changed
successfully
On a system with iSCSI ports, for port A3 change the IP address:
# set host-parameters ip 10.134.50.6 port a3 iscsi-ip-version ipv4
WARNING: This change will take effect immediately. Changes may affect access to
data. Are you sure? yes
Success: Command completed successfully. - The host parameters were changed
successfully
Specify that iSCSI ports will use IPv6 addressing:
# set host-parameters iscsi-ip-version ipv6
Success: Command completed successfully. - iSCSI parameter(s) were changed
successfully.
See also • restart
• set iscsi-parameters
• show host-parameters

Table of Contents

Other manuals for HP P2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 and is the answer not in the manual?

HP P2000 Specifications

General IconGeneral
Drive SupportSAS
ControllerDual Controller options available
Host Interface6Gb SAS, 8Gb FC, 1Gb iSCSI
RAID LevelsRAID 0, 1, 5, 6, 10
Storage TypeSSD
Hot-swappable ComponentsDrives, controllers, power supplies, fans
Dimensions8.9 x 44.8 x 63.5 cm (3.5 x 17.6 x 25 inches)
Drive BaysUp to 12 LFF or 24 SFF drive bays per enclosure