HP P2000 G3 MSA System CLI Reference Guide 175
Example Show the cache parameters for the system and for volume V1:
# show cache-parameters V1
System Cache Parameters
-----------------------
Operation Mode: Active-Active ULP
Controller A Cache Parameters
-----------------------------
Write Back Status: Enabled
CompactFlash Status: Installed
Cache Flush: Enabled
Controller B Cache Parameters
-----------------------------
Write Back Status: Enabled
CompactFlash Status: Installed
Cache Flush: Enabled
Volume Cache Parameters
-----------------------
Serial Number: SN
Name: V1
Cache Write Policy: write-back
Cache Optimization: standard
Read Ahead Size: Default
Basetypes cache-settings
cache-parameter
status
See also set cache-parameters