EasyManuals Logo

HP P2000 Reference Guide

HP P2000
448 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #204 background imageLoading...
Page #204 background image
204 Alphabetical list of commands
SIP-Gateway
iSCSI only. Secondary gateway IP address. This field is only displayed during failover.
SIP-Netmask
iSCSI only. Secondary subnet mask IP address. This field is only displayed during failover.
MAC(S)
iSCSI only. Secondary MAC address. This field is only displayed during failover.
Example Show port information for a system with two FC ports:
# show host-parameters
Ports Media Target ID Status Speed(A) Speed(C)
----------------------------------------------------------------
A1 FC(L) WWPN Up 8Gb Auto
Topo(C) PID
------------
Loop 0
A2 FC(-) WWPN Disconnected Auto
Topo(C) PID
------------
Loop
----------------------------------------------------------------
Show port information for a system with two iSCSI ports:
# show host-parameters
Ports Media Target ID Status Speed(A) Speed(C)
------------------------------------------------------------------------------
A1 iSCSI IQN Up 1Gb 1Gb
IP-Ver PIP PIP-Gateway PIP-Netmask MAC
--------------------------------------------------------------
IPv4 10.134.9.100 10.134.0.1 255.255.0.0 00:C0:FF:29:00:24
A2 iSCSI IQN Up 1Gb 1Gb
IP-Ver PIP PIP-Gateway PIP-Netmask MAC
--------------------------------------------------------------
IPv4 10.134.9.101 10.134.0.1 255.255.0.0 00:C0:FF:29:00:23
------------------------------------------------------------------------------
Show port information for a system with two SAS ports:
# show host-parameters
Ports Media Target ID Status Speed(A) Speed(C)
--------------------------------------------------------------
A1 SAS WWPN Disconnected
Topo(C) Width
--------------
Direct 4
A2 SAS WWPN Disconnected
--------------------------------------------------------------
Topo(C) Width
--------------
Direct 4
--------------------------------------------------------------
Basetypes • port
• status

Table of Contents

Other manuals for HP P2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 and is the answer not in the manual?

HP P2000 Specifications

General IconGeneral
Drive SupportSAS
ControllerDual Controller options available
Host Interface6Gb SAS, 8Gb FC, 1Gb iSCSI
RAID LevelsRAID 0, 1, 5, 6, 10
Storage TypeSSD
Hot-swappable ComponentsDrives, controllers, power supplies, fans
Dimensions8.9 x 44.8 x 63.5 cm (3.5 x 17.6 x 25 inches)
Drive BaysUp to 12 LFF or 24 SFF drive bays per enclosure