HP P2000 G3 MSA System CLI Reference Guide 219
SIP-Netmask
iSCSI only. Secondary subnet mask IP address. This field is only displayed during failover.
MAC(S)
iSCSI only. Secondary MAC address. This field is only displayed during failover.
Example Show port information for a system with two FC ports:
# show ports
Ports Media Target ID Status Speed(A) Speed(C)
----------------------------------------------------------------
A1 FC(L) WWPN Up 8Gb Auto
Topo(C) PID
------------
Loop 0
A2 FC(-) WWPN Disconnected Auto
Topo(C) PID
------------
Loop
----------------------------------------------------------------
Show port information for a system with two iSCSI ports:
# show ports
Ports Media Target ID Status Speed(A) Speed(C)
------------------------------------------------------------------------------
A1 iSCSI IQN Up 1Gb 1Gb
IP-Ver PIP PIP-Gateway PIP-Netmask MAC
--------------------------------------------------------------
IPv4 10.134.9.100 10.134.0.1 255.255.0.0 00:C0:FF:29:00:24
A2 iSCSI IQN Up 1Gb 1Gb
IP-Ver PIP PIP-Gateway PIP-Netmask MAC
--------------------------------------------------------------
IPv4 10.134.9.101 10.134.0.1 255.255.0.0 00:C0:FF:29:00:23
------------------------------------------------------------------------------
Show port information for a system with two SAS ports:
# show ports
Ports Media Target ID Status Speed(A) Speed(C)
--------------------------------------------------------------
A1 SAS WWPN Disconnected
Topo(C) Width
--------------
Direct 4
A2 SAS WWPN Disconnected
--------------------------------------------------------------
Topo(C) Width
--------------
Direct 4
--------------------------------------------------------------
Basetypes • port
• status
See also • set host-parameters